Xtramus NuTAP-S61 V1.2 Manual de usuario Pagina 28

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 75
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 27
28
B. NuTAP-S61 HyperTerminal Command – counter
Command Descriptions – counter
The counter show command allows you to view all NuTAP-S61’s counter report, as
well as hardware temperature. You can also add additional commands behind the
counter show command as listed down below:
The counter show usc [a0 | a1] [group=0 | group=1] command allows you
to view NuTAP-S61’s USC (Universal Stream Counter) report of its Network
Port (A0/A1) and the USC group. For example, to view the USC in USC
group 0 for Network Port A0, please input the command “counter show usc
a0 group=0”.
show
usc
configure
The counter show configure command allows you to view
USC’s settings.
clear
The counter clear command allows you to clear all counters.
show
The refreshtime show command allows you to view the refresh time for the
report.
refreshtime
set
The refreshtime set command allows you to set the refresh time (in
seconds) for the report.
The counter setusc command allows you to configure NuTAP-S61’s USC (Universal
Stream Counter) settings. Please refer to the sections down below for detailed
descriptions. Also, to view command lists for USC settings, you can input “counter
help setusc”.
The counter setusc [a0 | a1] [group=0 | group=1] baseaddress [da
| sa | vid | mpls | dip | sip | dp | sp | vlancos | vid&vlancos] <value>
command allows you to change the specific base address for
NuTAP-S61’s certain Network Port (A0/A1) and the USC group.
Please refer to the table down below for command initial reference:
DA: Destination Address
SA: Source Address
VID: VLAN ID
MPLS: Multi-Protocol Label
Switch
DIP: Destination IP Address
SIP: Source IP Address
DP: Destination Port
SP: Source Port
VLANCOS: VLAN Class of
Service
VID&VLANCOS: VLAN ID and
VLAN Class of Service
baseaddress
For example, to set the USC in source IP address of USC group 0 for
Network Port A0 to 192.168.1.1, please input the command “counter
setusc a0 group=0 baseaddress sip 192.168.001.001”.
The setusc [a0 | a1] [group=0 | group=1] mode [normal | jitter]
command allows to change the mode for NuTAP-S61’s certain
Network Port (A0/A1) and the USC group. There are two modes
available here:
Normal: The USC will run
under normal mode.
Jitter: The USC will run under
jitter mode.
mode
For example, to set the mode of USC group 0 for Network Port A0 to
normal, please input the command “counter setusc a0 group=0
mode normal”.
counter
setusc
enable/disable
The setusc [a0 | a1] [group=0 | group=1] [enable | disable]
command allows you to enable/disable NuTAP-S61’s certain Network
Port (A0/A1) and the USC group. For example, to enable USC group
0 for Network Port A0, please input the command “counter setusc a0
group=0 enable”.
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
Vista de pagina 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 74 75

Comentarios a estos manuales

Sin comentarios