Click on the Set Stream Counter to bring it out.
For explanation purpose, Stream Counter is divided into three sections. In the upper
part, Trigger A is set from the start of packet (Offset: 0) with content (Data: FF FF FF
FF FF FF) of 6 bytes (Length: 6). Please note that for XM-2301(G), the maximum
length of trigger for Stream Counter is 6 bytes.
There are three combinations of Trigger. In addition to Trigger A (Offset: 0) and Trigger
B (Offset: 6), Trigger C is either of 12 bytes of offset or X-Trailer set from NuStreams
chassis.
In the middle part, 14 bytes of Index Offset value is set from the start of packet to start
of Cos and VID field.