Xtramus DApps-MPT V1.4 Manual de usuario Pagina 239

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 395
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 238
239
E-mail: sales@xtramus.com
Website: www.Xtramus.com
XTRAMUS TECHNOLOGIES
®
D. Learning
Enable Learning: As shown in the figures down below, enabling this function allows learning
packets transmitted to the DUT before test packets are transmitted. If you disable this function, no
learning packets will be transmitted.
Frame Count: Repeat frame count per learning packets burst.
Frame Gap: Duration time between learning frames.
Tx Pkt Timeout: If the system fails to send the learning packet within the time you set in TxPKT
Timeout field, the packet will be drop.
Learning by Sequence: This function activates learning function in each test cycle.
Vista de pagina 238
1 2 ... 234 235 236 237 238 239 240 241 242 243 244 ... 394 395

Comentarios a estos manuales

Sin comentarios