B. Flow Control Test
Perform flow control test on DUT in layer 2 with different speeds, mode and various configurations. It tests
the performance when the DUT is connected to media with varied kinds of speed and direction.
PT2-FC-10H-100H (10Mbps Half 100Mbps Half),
PT2-FC-100H-10H (100Mbps Half 10Mbps Half),
PT2-FC-10F-100F (10Mbps Full 100Mbps Full),
PT2-FC-100F-10F (100Mbps Full 10Mbps Full),
PT2-FC-100F-1G (100Mbps Full 1000Mbps Full),
PT2-FC-1G-100F (1000Mbps Full 100Mbps Full),
PT2-FC-FULL (Perform Layer 2 Flow Control tests by two groups with different media type such as
100Mbps and 1000Mbps for DUT ports with different maximum speeds.)
C. Broadcast Test
Broadcasting refers to transmitting packets that will be received (conceptually) by every device on the
network.
Perform broadcast test on DUT in layer2 with different speeds, mode and various configurations. These
following tasks transmit broadcast frames (Destination Address: FF:FF:FF:FF:FF:FF).
PT2-BC-10H, (10Mbps, Half Duplex)
PT2-BC-10F, (10Mbps, Full Duplex)
PT2-BC-100H, (100Mbps, Half Duplex)
PT2-BC-100F, (100Mbps, Full Duplex)
PT2-BC-1G, (1Gbps, Full Duplex)
PT2-BC-FULL (Perform Layer 2 Broadcast test by two groups with different media type such as
100Mbps and 1000Mbps for DUT ports with different maximum speeds.)